Building Efficiency Advisors
Building Science Diagnostics for Homes & Local Businesses
Stop guessing where energy is lost. We provide comprehensive, diagnostic energy audits and building envelope testing to solve comfort issues, eliminate drafts, and reduce operating overhead.
Approach
Data-Driven Building Performance, Zero Sales Pressure
Most property owners only think about energy efficiency when an HVAC system fails or utility bills spike. At Anomaly, we treat your building as a complete, interconnected system. Using diagnostic testing equipment, we evaluate the boundary between conditioned space and the outside elements.
Whether you are troubleshooting persistent temperature imbalances in a family home or curbing operating costs in an office space, our assessments deliver clear, prioritized roadmaps rooted in building science.
Blower Door
Calibrated fan + manometer
Whole-building air leakage, measured in CFM50 and ACH50.
Infrared Imaging
Thermal camera survey
Insulation voids, thermal bridging, and air paths behind finished surfaces.
Digital Manometer
Pressure diagnostics
Zone-to-zone pressure, duct leakage, and combustion appliance zone depressurization.
Residential Assessments · Single-Family & Multi-Family
Residential Energy Diagnostics
Targeted Comfort, Indoor Air Quality, and Envelope Integrity
From drafty additions and cold floors to unmanageable seasonal heating bills, comfort issues in a home are almost always symptoms of building envelope failure. Our residential assessments pinpoint the root causes of energy loss before you spend thousands on equipment upgrades or cosmetic repairs.
Core Diagnostic Scope
-
Blower Door Depressurization Testing: Measuring whole-house air leakage rates to identify unsealed bypasses, attic penetrations, and exterior envelope gaps.
-
Infrared Thermal Imaging: Detecting missing, settling, or damaged insulation within finished exterior walls, rim joists, and ceiling assemblies.
-
Combustion Safety & Depressurization Testing: Verifying safe mechanical draft conditions and testing for carbon monoxide risks across natural gas appliances.
-
HVAC Distribution & Duct Leakage Review: Evaluating supply and return airflow imbalances, ductwork air sealing, and thermal bridging.
-
Health & Durability Inspection: Inspecting ventilation rates, moisture intrusion risks, and indoor air quality concerns.
What You Receive
A Prioritized Scope of Work A clear, staged plan distinguishing immediate air-sealing priorities from long-term capital investments.
Actionable ROI Objective recommendations you can hand to any mechanical or insulation contractor with exact specifications.
Small Commercial Assessments · Offices, Retail & Mixed-Use
Small Commercial Energy Diagnostics
Operational Efficiency & Overhead Reduction for Local Facilities
In small commercial spaces, uneven indoor temperatures and inefficient building envelopes affect more than just utility expenses—they impact employee productivity, client comfort, and equipment longevity. We tailor our assessments specifically to light commercial footprints, delivering actionable insights without the unnecessary complexity of industrial-scale energy audits.
Core Diagnostic Scope
-
Light Commercial Envelope Review: Identifying air infiltration points, draft paths, and thermal deficiencies across storefront assemblies, rooflines, and exterior partitions.
-
Operational & Utility Baseline Analysis: Reviewing historical electric and gas consumption trends to uncover seasonal baseload waste and occupancy-driven spikes.
-
Zoning & Mechanical Delivery Diagnostics: Assessing conditioned air delivery, setback controls, and ventilation efficiency across active business zones.
-
Prioritized Facility Roadmap: Clear payback estimates outlining quick-payback air-sealing measures, lighting upgrades, and mechanical maintenance points.
Ideal Facility Types
- Independent professional offices (medical, legal, advisory, creative)
- Retail storefronts & boutiques
- Mixed-use residential/commercial buildings
- Standalone branch locations & light commercial studios
Scalable Facility Solutions
While our day-to-day diagnostics focus on standalone offices, retail spaces, and boutique commercial footprints, our technical capacity scales to match larger footprints, complex multi-zone mechanical layouts, and multi-point air barrier testing.
Have a larger facility or unique testing requirement? Contact our team to discuss your project specifications.
Process
Intake → Diagnostics → Modeling → Delivery
- 01
Intake & Utility Baseline
We gather basic property details, square footage, mechanical configurations, and recent utility data.
- 02
On-Site Diagnostics
A structured, non-invasive on-site assessment using calibrated testing equipment to inspect envelope and mechanical performance.
- 03
Data Analysis & Modeling
We cross-reference test data against your building's footprint and historical usage patterns.
- 04
Independent Delivery
A clean, prioritized assessment report detailing exact findings, defect locations, and an unbiased roadmap for improvement.
Intake
Request an Energy Assessment
Tell us about the property. We'll follow up to schedule the on-site diagnostics.